TM70/3-10 & i-Kontrol Console RC System
U035.3-TM70_Console_Sys
68
22.1.2 Relay Outputs (Terminal RL1)
The connections shown in Table 25 are for the four possible relays of RL1.
Table 27. A1P4RCAN RL1 Relay Wiring*
*K1 through K4 relays rated at 250V@8A each.
Relay
Pin
Function
K1
1
Normally Closed (NC)
2
Common
3
Normally Open (NO)
K2
4
Normally Closed (NC)
5
Common
6
Normally Open (NO)
K3
7
Normally Closed (NC)
8
Common
9
Normally Open (NO)
K4
10
Normally Closed (NC)
11
Common
12
Normally Open (NO)
22.1.3 Analog Output (Terminal RL2)
Table 28. Analog Output RL2 Wiring
Pin
Name
Function
1
VOUT Analog Output
2
GND Midpoint of Potentiometer
3
–V Power supply Negative (-50V min.)
4
+V
Power supply Positive (50V max.)
22.1.4 Tele-Teaching (only V3.1 Software or Higher)
The following properties of the Analog Output can be set using Tele-Alignment:
Maximum and minimum values,
Polarity inversion
Acceleration or deceleration ramp, and
Curve type.
To configure the card for Tele Alignment mode, a bridge must be installed in Jumper P5 (see
Figure 46).
Vista de pagina 75
1 2 ... 71 72 73 74 75 76 77 78 79 80 81 ... 102 103