Operation and Installation Manual
2013 Cervis, Inc.
Modules: LA70M AC/LA70M DC
I3 Jumper
ID selector code / ID codes: “2” to “F” / ID =”3” by default
I2 jumper (Not available functioality)
Module LED Status
HARDWARE OK –green blinking- / ERROR –switched off-
Fast assembly
By magnets (standard configuration)
External dimensions
80 mm x 160 mm x 65 mm (Length x Width x Height)
Table 21: LA70M EX Specifications
Modules: LA70M AC/LA70M DC
DC power supply
Provided by the Master module
Operating temperatura range
-20/+70 ºC
IP ingress protection rating
IP67
Maximum range
50 meters
External connections
2 x M12 connectors -5 poles- (male - female)
Maximum number of expansions
2 (for each Master module)
LA70M XX / LA70M EX connection
cable
10 meters M12 –female/male- (supplied as spare part)
LED signalling
Hardware OK –green blinking- / ERROR –switched off-
Fast assembly
By magnets (standard configuration)
External dimensions
82 mm x 80 mm x 65 mm (Length x Width x Height)
Table 22: PC Enclosure Specifications
Material
Polycarbonate Ingress Protection IP67 EN 60529
Base colour
RAL 7035 Impact Resistance IK07 EN 62262
Cover colour
Clear transparent Electrical Isulation Totally insulated
Cover screws material
Stainless steel Halogen free SI / DIN-VDE 0472 Part 815
Gasket material
Polyurethane UV resistance UL 508
Temperatures
Flammability rating UL 746 C 5: UL 94 5V
Short term
-40…..+120 ºC Glow Wire Test IEC (695-2-1) ºC:960
Continous
-40…..+ 80 ºC NEMA Class NEMA 1,4,4X,12,13