20.0 IN4D Option
20.1 Description
The IN4D card provides a four (4) digital input interface when connected to the TM70 receiver.
The card is connected as a single-card using the receiver P16 connector. The IN4D can also be
used as a multi-digital input card using the INCAN option as an alternative.
The IN4D is a four digital-to-analog signal converter. Each of the four digital signals IN1, IN2,
IN3, and IN4 are converted to a 0 3V analog signal. See Figure 38.
Digital inputs IN1, IN2, IN3, and IN4 use the following voltages with reference to Connector 13,
Pin 6 (GND):
0 to 4V = deactivated 0 logic state
8 to 28V = activated 1 logic state
Figure 38. IN4D Digital-to-Analog Card Connector 13, Pins 1 through 6
CAUTION
Do not apply voltages greater than 28V. Input voltages greater
than 28V will damage the IN4D card.
The IN4D can provide a voltage of 12 to 20volts that can be used directly from Connector 13:Pin
1 as shown in .
Figure 39. IN4D 12 to 20V Voltage Source
+VI
IN1
IN2
IN3
IN4
GND
IN4D
1
2
3
4
5
6
I3
1
2
3
4
5
6
I1
+VI
IN1
IN2
IN3
IN4
GND
IN4D
1
2
3
4
5
6
I3
1
2
3
4
5
6
I1