Table 5. Receiver Status LED Fault Identification
POWER
Power Supply OK
Power Supply NOT OK
HARDOK
Board OK Slow: fault in the board
Fast: error in EEPROM
Fault in the board
SIGNAL
RF signal OK RF signal detection in
SCANNING Mode
The receiver is not receiving RF
signals
DATA
Is receiving the correct data from
a TM701
Fault in the board
ID
ID Code OK1 ID NOT recognized
Note: The DATA and ID LED’s flash dimly when data and the ID code are received correctly,
but the Start command has not yet been received. Once the START button is pushed ON, the
DATA and ID LED’s will brightly as normal.
CAN_RUN
Operating status Pre-operating status CAN communication non-active
CAN_ERR
Communication OK Communication error CAN controller disconnected
7.2 Returning Equipment for Repair
If you find a problem with the equipment:
1. Contact our Customer Service.
2. Discuss your problem with the Cervis technician. In many cases the problem can
be resolved over the telephone and thus not require you to return any equipment.
3. When equipment is determined to need service, the technician will issue an
Return Material Authorization (RMA) number to you.
4. Return the defective device to our Customer Service Department. Please:
• Include a description of the problem and the status of the LEDs.
• Clearly mark your issued RMA number on the outside of the package.
Note: Please address all equipment returned to Cervis, Inc. to the attention of our Customer
Service Department, together with a description of the problem and the status of all LED’s. It
is our intention to make the necessary repairs quickly and return the system to you as soon
as possible.
Note: If the transmitter becomes inoperable, a spare can be quickly substituted by following
the instructions in Heading10.0.