10
5.0 Starting Up
Proceed with caution upon initial Startup! Disconnect the power
supply from the motors before applying power to the Receiver to
prevent unintended movement of the equipment in case of
improper connections.
1. Once the receiver has been connected, disconnect the power supply to the
motorsby removing the fuses for exampleand then power up the receiver.
The receiver enters into a SCANNING mode upon power-up; the receiver LED
power-up states are defined in Table 2.
Table 2. Receiver LED States During Power-Up
LED
State
Indication
POWER (1) ON
Power supply is correct
HARDOK (2) ON
Absence of faults on the boards
SIGNAL (3)
OFF
Blinks
Channels are signal free
An RF signal on the channels
DATA (4)
OFF
Blinks
Another TM70 system is not active in the area
Another TM70 system is active in the area
ID (5) OFF
System Transmitter not on.
CAN_RUN (6) ON
Indicates that CAN communications with expansion
boards are OK.
CAN_ERR (7) OFF
Figure 7. LEDs by Number