59
TM70Bi V3.1 (03/09) 1121174.pdf
IKUSI reserves the right to change this information without prior notice.
ANALOGUE OUTPUT
The analogue output is connected through RL2 connector with the following signals (Imax=15mA):
Pin
Function
1
Analogue Output
2
Potentiometers middle point
3
Negative power supply (Minimun: -50V)
4
Positive power supply (Maximun: 50V)
TELE-TEACHING (V3.1 OF SOFTWARE OR HIGHER VERSIONS)
Through Tele-Alignment can set the maximum and minimum values, the polarity inversion, acceleration or
deceleration ramp and curve type of the analogue output. To change to Tele-Alignment mode is necessary to
introduce a bridge in the jumper P5 (see Jumpers configuration). Only available for TM70 consol box from
3.1 software version or higher.
CANL
CANH
+VI GND
CAN
ADDRESS
TELEALIGNMENT
Relay outputs
Analogue output