Cervis TM70 Manual de instalación Pagina 27

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 76
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 26
24
TM70Bi V3.1 (03/09) 1121174.pdf
IKUSI reserves the right to change this information without prior notice.
9.1 - INTRODUCTION
The TM70 system with CANopen interface is integrated in CANopen networks where it will work in slave
mode. It handles the Bus the state of the Pushbuttons of the TM70 transmitter, such that any external
device can react consequently.
The functionality of the system is according the CiA DS-301 v4.0.2. specification. The implemented profile
is described in CiA DS-401 v2.1 (Input/Output standard), where the pushbutton manoeuvres
are
considered as digital inputs.
The implemented characteristics are:
NMT Functioning: slave.
NodeID: EEPROM configurable, from 1 to 127.
Baud rate: EEPROM configurable. Supported speeds: 10, 20, 50, 100, 125, 250, 500, 800 and 1000
Kbps.
Error control: it can work Heartbeat” as well as Node/life guarding. EEPROM configurable.
Number of PDOs: 1 TPDO (manoeuvres state).
EEPROM parameters recording: not supported.
9.2 - CAN BUS CONNECTION
In order to connect the CAN bus to the LR72 pcb, it contains a 5 poles connector (P4).